浏览:991 回答:1


 ***************************************************************
 *            ANSYS 2021 R1          LEGAL NOTICES             *
 ***************************************************************
 *                                                             *
 * Copyright 1971-2021 ANSYS, Inc.  All rights reserved.       *
 * Unauthorized use, distribution or duplication is            *
 * prohibited.                                                 *
 *                                                             *
 * Ansys is a registered trademark of ANSYS, Inc. or its       *
 * subsidiaries in the United States or other countries.       *
 * See the ANSYS, Inc. online documentation or the ANSYS, Inc. *
 * documentation CD or online help for the complete Legal      *
 * Notice.                                                     *
 *                                                             *
 ***************************************************************
 *                                                             *
 * THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION       *
 * INCLUDE TRADE SECRETS AND CONFIDENTIAL AND PROPRIETARY      *
 * PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS.    *
 * The software products and documentation are furnished by    *
 * ANSYS, Inc. or its subsidiaries under a software license    *
 * agreement that contains provisions concerning               *
 * non-disclosure, copying, length and nature of use,          *
 * compliance with exporting laws, warranties, disclaimers,    *
 * limitations of liability, and remedies, and other           *
 * provisions.  The software products and documentation may be *
 * used, disclosed, transferred, or copied only in accordance  *
 * with the terms and conditions of that software license      *
 * agreement.                                                  *
 *                                                             *
 * ANSYS, Inc. is a UL registered                              *
 * ISO 9001:2015 company.                                      *
 *                                                             *
 ***************************************************************
 *                                                             *
 * This product is subject to U.S. laws governing export and   *
 * re-export.                                                  *
 *                                                             *
 * For U.S. Government users, except as specifically granted   *
 * by the ANSYS, Inc. software license agreement, the use,     *
 * duplication, or disclosure by the United States Government  *
 * is subject to restrictions stated in the ANSYS, Inc.        *
 * software license agreement and FAR 12.212 (for non-DOD      *
 * licenses).                                                  *
 *                                                             *
 ***************************************************************

      Date: 04/30/2024      Time: 22:44:16  

     ___________________________________________________
     |                                                 |
     |  Livermore Software Technology, LLC             |
     |                                                 |
     |  7374 Las Positas Road                          |
     |  Livermore, CA 94551                            |
     |  Tel: (925) 449-2500  Fax: (925) 449-2507       |
     |  www.lstc.com                                   |
     |_________________________________________________|
     |                                                 |
     |  LS-DYNA, A Program for Nonlinear Dynamic       |
     |  Analysis of Structures in Three Dimensions     |
     |  Date    : 10/29/2021    Time: 15:50:06         |
     |  Version : smp s R12                            |
     |  Revision: R12.1-190-gadfcdf9018                |
     |                                                 |
     |  Features enabled in this version:              |
     |    Shared Memory Parallel                       |
     |    FFTW (multi-dimensional FFTW Library)        |
     |    Interactive Graphics                         |
     |    ANSYSLIC enabled                             |
     |    MADYMO indirect coupling (7.2 or higher)     |
     |                                                 |
     |  Licensed to:                                   |
     |  Issued by  : ANSYS                             |
     |                                                 |
     |  Platform   : WINDOWS X64 (SSE2)                |
     |  OS Level   : Windows 8/10 & Srv 2016/2019 uam  |
     |  Compiler   : Intel Fortran XE 2017 MSVC++ 2017 |
     |  Hostname   : BJ-20230611WWVA                   |
     |  Precision  : Single precision (I4R4)           |
     |                                                 |
     |  Unauthorized use infringes LSTC copyrights     |
     |_________________________________________________|


 Command line options: i=E:\Users\Administrator\Desktop\Shangbin\Structure.k 
                       ncpu=32 
                       memory=1000m

 Input file: E:\Users\Administrator\Desktop\Shangbin\Structure.k                             

 The native file format       : 32-bit small endian
 Memory size from command line:  1000000000
 Memory option                : AUTO selected
 allocating  memory to  1000000000 d         544 Initial allocation

 ********  notice  ********  notice  ********  notice  ********
 *                                                            *
 * This is the LS-DYNA Finite Element code.                   *
 *                                                            *
 * Neither LST nor the authors assume any responsibility for  *
 * the validity, accuracy, or applicability of any results    *
 * obtained from this system. Users must verify their own     *
 * results.                                                   *
 *                                                            *
 * LST endeavors to make the LS-DYNA code as complete,        *
 * accurate and easy to use as possible.                      *
 * Suggestions and comments are welcomed.  Please report any  *
 * errors encountered in either the documentation or results  *
 * immediately to LST through your site focus.                *
 *                                                            *
 * Copyright (C) 1990-2021                                    *
 * by Livermore Software Technology, LLC                      *
 * All rights reserved                                        *
 *                                                            *
 ********  notice  ********  notice  ********  notice  ********

 Beginning of keyword reader                                   04/30/24 22:44:16
 expanding   memory to   565432040 d   173915466  
 expanding   memory to   596843820 d   173915466  
 expanding   memory to   596873820 d   173915466  
 expanding   memory to   596933820 d   173915466  
 expanding   memory to   596954082 d   173915466  
 expanding   memory to   722613524 d   173915466  
 expanding   memory to   848254644 d   173915466  
 expanding   memory to   848276968 d   173915466  
 expanding   memory to   848391968 d   173915466  
 
 *** Warning 11080 (KEY+1080)
     *RIGIDWALL_GEOMETRIC_FLAT ID 2 has length less than or equal to 0.0
     LENL = 0.0000E+00; LENM = 0.0000E+00;
 expanding   memory to   848417636 d   173915466  
 expanding   memory to   867745310 d   173915470  
 expanding   memory to   887068184 d   173915470  
 expanding   memory to   906401062 d   173915470  
 expanding   memory to   925723940 d   173915470  
 expanding   memory to  1138275598 d   173915470  
 
 *** Warning 70025 (OTH+25)
     Memory is set 138275598 words short
     increase the memory size to 1138275598
 expanding   memory to  1157598480 d   173915470  
 
 *** Warning 70025 (OTH+25)
     Memory is set 19322882 words short
     increase the memory size to 1157598480
 expanding   memory to  1176921358 d   456598993  
 
 *** Warning 70025 (OTH+25)
     Memory is set 19322878 words short
     increase the memory size to 1176921358
 expanding   memory to  1176943658 d   456598993  
 
 *** Warning 70025 (OTH+25)
     Memory is set 22300 words short
     increase the memory size to 1180921358
 expanding   memory to  1192648300 d   456598999  
 
 *** Warning 70025 (OTH+25)
     Memory is set 11726942 words short
     increase the memory size to 1192648300
 expanding   memory to  1208352940 d   456598999  
 
 *** Warning 70025 (OTH+25)
     Memory is set 15704640 words short
     increase the memory size to 1208352940

 Memory required to process keyword     :       1208m 
 Additional dynamic memory required     :  456599007  

 contracting memory to           1 d   173915476 end of keyword reader

 LS-DYNA will perform a structural only analysis 

                                                                         
                         ls-dyna smp.190 s              date 10/29/2021
 expanding   memory to        2777 d         610 material, node and element data
 expanding   memory to        2855 d         624 mat add general damage 0
 expanding   memory to        2875 d         624 material added airbag porosity leakage 
 expanding   memory to        2883 d         624 material properties
 expanding   memory to        2889 d   239189503 element data for composite material
 expanding   memory to        2903 d  4741419054 gradient of damage data
 expanding   memory to        2977 d  4976988685 user control for contact interfaces
 contracting memory to        2959 d  4976988685 thermal expansion 0
 expanding   memory to        2961 d  4976988685 state of charge expansion 0
 expanding   memory to        2963 d  4976988685 cross-sectional force definitions 0
 expanding   memory to    19325841 d  4976988697 temp index array for node sorting
 contracting memory to        2963 d  4996311579 just because?
 expanding   memory to    15707603 d  5034957367 arbitrary element numbering input
 contracting memory to        2964 d  6782829999 process element material data
 expanding   memory to        4971 d  6782829997 load curve data
 contracting memory to        3393 d  6782829997 user_define_loading_set
 expanding   memory to        3597 d  6782829997 regularize time history data
 contracting memory to        3397 d  6782829997 *DEFINE_ELEMENT_DEATH
 
 *** Warning 21374 (STR+1374)
     rigidwall ID 2 vectors n and l are not orthogonal
 expanding   memory to        3602 d  7202044413 contact interfaces
 expanding   memory to    38650358 d  7202044413 implicit contact 1
 expanding   memory to   164287480 d  7202044413 implicit contact 2
 contracting memory to        4602 d  7340987179 contact segment data 1
 expanding   memory to   183610356 d  7443422881 contact segment data 3
 contracting memory to        3602 d  7832516684 contact definition
 expanding   memory to        3620 d  7832516685 rigid body
 expanding   memory to   109752426 d  7876416865 contact friction
 expanding   memory to   175601730 d  7876416865 joints
 expanding   memory to   175601830 d  7964216497 rigid bodies for disp. termination
 expanding   memory to   175601884 d  7964216497 save d3plot control data
 expanding   memory to   175601886 d  8041508060 mat add cohesive 0
 expanding   memory to   175601888 d  8041508060 sensor_control for curve
 expanding   memory to   175601890 d  8041508060 flexible body 2
   convergence of normal check obtained in 139 iterations
   region 1 has 7317744 segments.
   number of independent regions where normal vectors
   are checked and if necessary reset =    1
   number of renumbered segments = 0
 
 *** Warning 30128 (INI+128)
     Massless nodes
     The following massless nodes were found
 17902 17923 17924 17925 17926 17927
 17928 17929 17930 17931 17932 17933
 17934 17935 17936 17937 17938 17939
 17940 173221 173222
 
 *** Warning 30131 (INI+131)
     total number of massless nodes = 21

     slave surface of interface   = 1
     type                         =         4
     surface timestep             = 3.267E-08
     controlling slave node ID    = 19496138
     part ID of slave node        = 2
     current minimum time step    = 3.267E-08

 The LS-DYNA time step size should not exceed     3.267E-08
 to avoid contact instabilities.  If the step size is
 bigger then scale the penalty of the offending surface.

 S t o r a g e   a l l o c a t i o n   

 Memory required to begin solution      :    1209M
 Additional dynamically allocated memory:    8110M
                                   Total:    9318M

各位老师,最后一行是“Initialization completed”,后面就没有任何信息了,没有提示error也不显示termination,这是什么问题?


邀请回答 我来回答

全部回答

(1)
默认 最新
用户_51739
我也有这个问题,请问解决了吗
9月3日
评论 点赞

没解决?试试专家一对一服务

换一批