ABAQUS问题
浏览:1223 回答:1
Kinematic *contact pair references a rigid surface that is also included in a general contact definition (which incorporates all analytical rigid surfaces.) this could produce incorrect results. Use penalty contact pair instead of kinematic contact pair.
求大神指点